7
Fig. 10 The adapter plates should be
preinstalled onto the MagnaValve and
the assembly installed as a single unit,
The entire MagnaValve assembly can
be temporarily positioned and held into
place by using vise-grip or similar pli-
ers and then the bolts can be installed
and tightened.
Fig. 11 The feed spout can now be rein-
stalled easily, since it bolts directly to the
special adapter plate. Be sure to use a
rubber gasket between the adaptor plate
and the feed spout. Do not use silicon rub-
ber or any other adhesive that will make it
difficult to remove the valve for inspection.
Fig. 10
Fig. 11
Note:Adding a nonmetallic 1” spacer
above and below the Magnavalve will
significantly improve MagnaValve per-
formance.